Start with Grundfos’s official spare-parts lookup and a dealer matched to your location. “Grundfos pressure transducer” is not a sufficient ordering specification. The pump, controller, production version, and sensor kit must agree before you buy.
Optional: flow calculator for treatment planning
INTERACTIVE WATER BALANCE / V1.0
Well Storage & Refill Calculator
Will usable stored water cover your entered demand sequence? Add each water-use stage, then compare the remaining water with the reserve you need to retain.
Calculation method and limits
Within a stage, flows are constant. End water = min(usable capacity, starting water + (refill − treatment − household flow) × minutes). The lowest balance in each constant-rate stage occurs at one of its endpoints. Inflow above capacity is not carried into the next stage. A balance below zero represents unmet demand, not physically available water.
The model works backward from the required reserve to find the least starting usable water that can retain that reserve throughout the sequence. If the required water exceeds usable capacity at any stage, no starting level within the entered capacity can cover that sequence. Arithmetic comparisons use a small floating-point tolerance.
Post-event refill time returns the reservoir to its entered starting level. It is not aquifer recovery time. If net refill is zero or negative and water was depleted, no finite refill time exists under those assumptions. A failed demand sequence has no valid recovery estimate.
Gallons alone do not establish delivery at pressure, sustainable well yield, drinking-water safety or an installation design. Source assessment, permitted operating levels, controls and equipment requirements need separate evidence. See the water-balance method, the worked example and the guide’s sources and review status.
Use the Official Parts and Purchase Routes
Grundfos’s spare-parts guide links to Product Center and explains how to choose a product, its production period, and the correct spare-parts list. Use that list to identify the component and service kit, rather than choosing a listing from its photograph.
The Grundfos US contact page provides the official purchase and dealer route. Ask the dealer to confirm compatibility in writing and quote the complete kit. This page does not claim a particular seller has stock or a current price.
Collect These Details Before Requesting a Quote
| Detail | What to send or verify |
|---|---|
| Pump and controller identification | Full model, product number, serial/production information, and the applicable manual. |
| Existing sensor identification | Clear photographs of accessible labels, part markings, and connector; do not open energized controls. |
| Pressure range and signal | The exact range, units, output type, and supply requirements specified for the controller. |
| Mechanical and cable connection | Thread standard, fitting arrangement, connector, cable length, and included seals or adapters. |
| Service-kit scope | Whether the quote is for the sensor alone, a complete kit, or another assembly. |
Reading an externally accessible label is different from removing a pressurized sensor. Have the installer retrieve information that requires opening controls or disturbing plumbing.
Why a Generic Transducer Can Be the Wrong Purchase
Two sensors can share a thread or pressure range while using incompatible electrical signals or connectors. A pressure switch is also not automatically interchangeable with a feedback transducer used by a variable-speed controller.
Grundfos SQ/SQE documentation distinguishes controller arrangements and accessories. Do not transfer a part number from another country, controller version, or catalog example to your system without confirmation. Ask whether the proposed kit supersedes an older number and what installation documentation applies.
Confirm the Fault Before Ordering
A low-pressure complaint or controller alarm alone does not prove that the sensor has failed. Supply, wiring, configuration, pump performance, and other conditions can require professional diagnosis. Record the exact alarm and what happened before it; do not bypass the sensor or change relief settings to keep the pump running.
Do not substitute an arbitrary fuse rating from a forum. Electrical checks, pressure isolation, sensor removal, and recommissioning must follow the exact equipment instructions. If the original part has been discontinued or identification remains uncertain, have Grundfos support or a qualified dealer establish the replacement path before purchase.
For a filter-sizing question rather than a controller fault, use the flow measurement guide and backwash checker. Those tools do not diagnose a transducer. This is a documentation-based compatibility guide; no sensor was physically tested and no listing is ranked by affiliate commission.
Common Questions
Can I buy any sensor with the same pressure range?
No. The electrical signal, supply, connector, controller compatibility, mechanical connection, and kit version must match as well. Confirm the replacement against the exact product information.
Does a CU 301 alarm prove the pressure sensor is bad?
No. Record the exact alarm and have the system diagnosed under the applicable manual. An alarm or low pressure is not enough to justify a sensor replacement or bypass.